EIB 5000

  • Specifications
  • Documentation
Specifications

Specifications

EIB 5281

EIB 5211

EIB 5181

Functional safety

Determined by the connected encoder and subsequent electronics (including their configuration); the EIB has no effect on the safe position

Encoder input

Interface

EnDat 2.1

EnDat 2.2

1 VPP/EnDat 2.1/EnDat 2.2

Ordering designation

EnDat01/EnDat02

EnDat229)

EnDat01/EnDat02/EnDat22

Electrical connection

17-pin M23 flange socket (female) with coupling ring

12-pin M12 flange socket

25-pin D-sub connector (female)

Voltage supply of encoder

The EIB passes the supply voltage from the subsequent electronics to the connected encoder

Cable length1)

< 6 m

< 100 m

Temperature sensor input

Quantity

3

Connectable sensors2)

KTY 84-130, PT 1000, PTC, PTC triplet3)

Evaluation accuracy tolerance

Typically: ±1 K; maximum: ±2 K

Time constant for temperature measurement

Please indicate when ordering

Set using DIP switches

Electrical connection

7-pin M17 flange socket (female)

6-pin header (male)

Cable length4)

< 6 m

< 20 m

Control output

Interface

EnDat 2.1

EnDat 2.2

1 VPP/EnDat 2.1/EnDat 2.2

Ordering designation

EnDat01/EnDat02

EnDat22

EnDat01/EnDat02/EnDat22

Electrical connection

17-pin M23 flange socket (male)

8-pin M12 flange socket

25-pin D-sub connector (male)

Cable length1)

< 50 m

< 50 m

< 3 m

Supply voltage

5 V ±10 %5)

3.6 V ... 14 V

5 V ±10 %5)

Power consumption6)

Typical: 200 mW; max. 300 mW

Typical: 160 mW; max. 210 mW

Typical: 250 mW; max. 350 mW

Temperature output

Emulation of PT 1000 behavior7)

Emulation of PT 1000 or KTY84-130 behavior7)

Emulation accuracy tolerance8)

Typically: ±3 K; maximum: ±4 K

Typically: ±3 K; maximum: ±4 K

Operating temperature

0 °C to 70 °C

Storage temperature

–30 °C to 70 °C

Vibration 55 Hz to 2000 Hz

Shock 11 ms

100 m/s2 (EN 60068-2-6)

300 m/s2 (EN 60068-2-27)

10 m/s2 (EN 60068-2-6)

30 m/s2 (EN 60068-2-27)

Protection EN 60529

IP65 (when engaged)

IP20

Altitude

< 2000 m above sea level

Mass

 0.5 kg

1) Applies only to HEIDENHAIN cables; be sure to consider the voltage drop

2) For further information, please refer to Temperature evaluation and Monitoring functions

3) Please select when ordering; EIB 5181 is configured using DIP switches

4) Observe the information from the motor manufacturer

5) Take the supply voltage range of the encoder into account

6) Without power or current consumption of the encoder; version with switching output: additional power consumption of 50 mW

7) See Emulation of PT 1000 behavior

8) Applies to cable lengths < 1 m

9) The encoder must be designed for connection to the EIB 5211