- Specifications
- Documentation
Specifications |
EIB 5281 |
EIB 5211 |
EIB 5181 |
Functional safety |
Determined by the connected encoder and subsequent electronics (including their configuration); the EIB has no effect on the safe position |
||
Encoder input |
|||
Interface |
EnDat 2.1 |
EnDat 2.2 |
1 VPP/EnDat 2.1/EnDat 2.2 |
Ordering designation |
EnDat01/EnDat02 |
EnDat229) |
EnDat01/EnDat02/EnDat22 |
Electrical connection |
17-pin M23 flange socket (female) with coupling ring |
12-pin M12 flange socket |
25-pin D-sub connector (female) |
Voltage supply of encoder |
The EIB passes the supply voltage from the subsequent electronics to the connected encoder |
||
Cable length1) |
< 6 m |
< 100 m |
|
Temperature sensor input |
|||
Quantity |
3 |
||
Connectable sensors2) |
KTY 84-130, PT 1000, PTC, PTC triplet3) |
||
Evaluation accuracy tolerance |
Typically: ±1 K; maximum: ±2 K |
||
Time constant for temperature measurement |
Please indicate when ordering |
Set using DIP switches |
|
Electrical connection |
7-pin M17 flange socket (female) |
6-pin header (male) |
|
Cable length4) |
< 6 m |
< 20 m |
|
Control output |
|||
Interface |
EnDat 2.1 |
EnDat 2.2 |
1 VPP/EnDat 2.1/EnDat 2.2 |
Ordering designation |
EnDat01/EnDat02 |
EnDat22 |
EnDat01/EnDat02/EnDat22 |
Electrical connection |
17-pin M23 flange socket (male) |
8-pin M12 flange socket |
25-pin D-sub connector (male) |
Cable length1) |
< 50 m |
< 50 m |
< 3 m |
Supply voltage |
5 V ±10 %5) |
3.6 V ... 14 V |
5 V ±10 %5) |
Power consumption6) |
Typical: 200 mW; max. 300 mW |
Typical: 160 mW; max. 210 mW |
Typical: 250 mW; max. 350 mW |
Temperature output |
Emulation of PT 1000 behavior7) |
– |
Emulation of PT 1000 or KTY84-130 behavior7) |
Emulation accuracy tolerance8) |
Typically: ±3 K; maximum: ±4 K |
– |
Typically: ±3 K; maximum: ±4 K |
Operating temperature |
0 °C to 70 °C |
||
Storage temperature |
–30 °C to 70 °C |
||
Vibration 55 Hz to 2000 Hz Shock 11 ms |
100 m/s2 (EN 60068-2-6) 300 m/s2 (EN 60068-2-27) |
10 m/s2 (EN 60068-2-6) 30 m/s2 (EN 60068-2-27) |
|
Protection EN 60529 |
IP65 (when engaged) |
IP20 |
|
Altitude |
< 2000 m above sea level |
||
Mass |
0.5 kg |
1) Applies only to HEIDENHAIN cables; be sure to consider the voltage drop
2) For further information, please refer to Temperature evaluation and Monitoring functions
3) Please select when ordering; EIB 5181 is configured using DIP switches
4) Observe the information from the motor manufacturer
5) Take the supply voltage range of the encoder into account
6) Without power or current consumption of the encoder; version with switching output: additional power consumption of 50 mW
7) See Emulation of PT 1000 behavior
8) Applies to cable lengths < 1 m
9) The encoder must be designed for connection to the EIB 5211