![](/fileadmin/redakteure/de/products/Interface_Elektroniken/EIB1500.jpg)
- Specifications
- Documentation
Specifications |
EIB 1512 |
EIB 1592 F |
EIB 1592 M |
Input |
|||
Interface |
1 VPP (encoder with distance-coded reference marks) |
||
Input frequency |
≤ 400 kHz |
||
Electrical connection |
2 x M23 flange connector (female), 12 pin |
||
Power supply for encoders |
DC 5 V ± 0.25 V (generated from power supply for EIB); ≤ 150 mA per encoder |
||
Cable length |
≤ 6 m |
||
Output |
|||
Interface |
EnDat 2.2 |
Fanuc Serial Interface |
Mitsubishi high speed interface |
Ordering designation |
EnDat 22 |
Fanuc 02 |
Mit 02-4 |
Calculation time tcal Clock frequency |
≤ 5 µs ≤ 16 MHz |
– |
– |
Electrical connection |
8-pin M12 flange socket (male) |
||
Cable length1) (with HEIDENHAIN cable) |
≤ 100 m |
≤ 20 m |
≤ 20 m |
Subdivision |
≤ 16 384-fold (depending on the encoder) |
||
Voltage supply |
3.6 V to 14 V DC |
||
Power consumption (max.) |
3.6 V: < 3.3 W 14 V: < 3.0 W (including current consumption of the scanning heads (IMmax = 150 mA) |
||
Current consumption (typical, without load) |
5 V: 130 mA + 1.4 x 2 x IMtyp |
||
Operating temperature Storage temperature |
0 °C to 70 °C –30 °C to 70 °C |
||
Vibration 55 to 2 000 Hz Shock 11 ms |
100 m/s2 (EN 60 068-2-6) 300 m/s2 (EN 60 068-2-27) |
||
Protection |
IP 65 |
||
Weight |
≈ 0.3 kg |
||
1) Because of the high power consumption (EIB + 2 encoders), the influence of the cable length (voltage drop) must be tested in detail |